Rebar retainer universal stand, protective layer 10-15 mm, 500 pcs.

Product code: 0101

The retainer is a flooring for creating a protective horizontal layer under the reinforcement on a solid base.

220,00
uah
x
pack
=
220,00 uah
220

The universal 10-15 mm stand retainer is used to fix fittings in a horizontal position when installing floor slabs, screed, industrial floors and other architectural solutions. The retainer of the protective layer is used to install a horizontal layer of concrete reinforcement or on any other rigid base. The special design of the retainer distributes the load over the entire area of the product, which in turn provides greater reliability under pressure of the reinforcement cage. The universal retainer is used for fittings with a diameter from 4 to 12 mm and provides a protective layer from 10 to 15 mm.

Main Features:

  • Recommended consumption is from 4 to 6 pcs/m2
  • Purpose of the retainer: For overlaps
  • Type of retainer: Stand
  • Retainer Material: Plastic
  • Thickness of the protective layer: 10 mm
  • Minimum armature diameter: 4 mm
  • Maximum diameter of the armature: 12 mm
  • Working position: Horizontal
  • Package Quantity: 500 pcs

Rebar clamps are an expendable material for the installation of a reinforcement frame for concrete, therefore they have a relatively low price. You can also buy fixers at wholesale prices. You will receive a favorable price offer. We have an individual approach to each client. Our specialists will calculate how many clamps per square meter you need.

Recommended consumption is from 4 to 6 pcs/m2
Purpose of the retainer: For overlaps
Type of retainer: Stand
Retainer Material: Plastic
Thickness of the protective layer: 10 mm
Minimum armature diameter: 4 mm
The maximum diameter of the armature: 12 mm
Working position: Horizontal
Package Quantity: 500 pcs

Optimize work on the construction site and ensure the reliability of the structure with the universal Protex rebar retainer. It is used to fix fittings in a horizontal position during the construction of floor slabs, screed, industrial floors and other architectural solutions. Our protective layer retainer guarantees the installation of a horizontal reinforcement layer on any rigid base. The unique design distributes the load evenly, providing greater reliability under the pressure of the reinforcement cage. It is suitable for fittings with a diameter of 4 to 12 mm and provides a protective layer with a thickness of 10 to 15 mm. Main Features: - Recommended consumption from 4 to 6 pcs/m2 - Ideal for floors - Material: durable plastic - Thickness of the protective layer: 10 mm - Suitable for fittings with a diameter of 4 to 12 mm - Installation in a horizontal position - In a package of 500 pieces, Protex rebar clamps are an integral material for mounting the reinforcement frame and are offered at low price. We have wholesale prices that will help you save money. Each client receives an individual approach, and we will help you determine the exact number of fixers needed for your project.

Attractive Product Description Protex Rebar Retainer universal stand, protective layer 10-15 mm, 500 pcs.: Improve the quality of your construction projects with the Protex Rebar Retainer universal stand! Our retainer is designed to fix the reinforcement in a horizontal position and ensures the reliability and strength of your reinforcement frame. Use the Protex Retainer universal 10-15 mm stand for the installation of floor slabs, screeds, industrial floors and other architectural solutions. Our retainer has a special design that evenly distributes the load over the entire area, providing greater reliability under the pressure of the reinforcement cage. With our universal retainer, you can use rebar with a diameter from 4 to 12 mm and get a protective layer from 10 to 15 mm. The durable plastic material of our retainer ensures durability and reliability of use. Main Features: - Recommended consumption from 4 to 6 pcs/m2 - Purpose of the retainer: For ceilings - Type of retainer: Rack - Material of the retainer: Plastic - Thickness of the protective layer: 10 mm - Minimum diameter of the reinforcement: 4 mm - Maximum diameter of the reinforcement: 12 mm - Working position: Horizontal - Quantity in the package: 500 pcs Ordering Protex Rebar retainer is a universal stand, you get a favorable price offer. Our company provides an individual approach to each client, and our specialists will help you determine the required number of clamps per square meter. Improve the quality of your construction with the Protex Rebar Retainer universal rack!

What are the retainers made of?

The material for the manufacture of fixators is secondary raw materials. We care about the environment and protect nature for future generations. Recycled plastic remains strong in future use. After all, they require the same quality from it as from ordinary plastic. It is not subject to corrosion and easily takes any shape, is not afraid of temperature changes, leaves resistance to high and low temperatures, does not deform.

What is the consumption of fixers per square meter?

Typically, 5 to 10 fasteners per square meter are used. For reliable fixation of the reinforcement, it is recommended to use from 5 to 10 fasteners per square meter. The smaller the diameter of the armature, the more retainers are used

What is the thickness of the protective layer?

The universal 10-15 mm locking stand provides a protective layer from 10 to 15 mm

What kind of fittings are these clamps suitable for?

The clamps are designed for fittings with a diameter of 6-16 millimeters. The smaller the diameter of the armature, the more retainers are used

How do I calculate the number of retainers?

The clamps are designed for fittings with a diameter of 8-16 millimeters. Typically, 5 to 10 fasteners per square meter are used. For reliable fixation of the reinforcement, it is recommended to use from 5 to 10 fasteners per square meter. The smaller the diameter of the armature, the more clamps are used.

How to choose the correct height of the retainer?

Reinforcing clamps allow you to achieve maximum strength and reliability in the construction of the supporting frame, contribute to the pouring of the exact thickness of the protective concrete layer between the formwork panels and the reinforcing mesh. The clamps allow you to place the reinforcement at the right distance from the base and walls of the formwork. The height of the clamps is selected based on 1/3 of the height of the protective layer.

What is the protective layer of concrete?

The protective layer of concrete is the distance from the outer face of the reinforced concrete element to the nearest reinforcing bar. The thickness of the protective layer of concrete should be selected, taking into account the purpose of reinforcement in structures. The working or constructive role of the reinforcement is taken into account; the type of structure (for example, a column, slab, beam, foundation element or wall); the diameter and type of reinforcement. This is due to the fact that too thin a layer will not fully perform its functions, and too thick a layer will negatively affect the reinforced frame and lead to increased costs.

How thick should the protective layer be?

  • at standard or low humidity in the room, the thickness of the protective layer of concrete should not be less than 20 mm.
  • in case of high humidity inside structures, the concrete thickness should be at least 25 mm.
  • during the construction of buildings, the reinforced concrete parts of which go out into the open atmosphere, the protective layer of concrete should be 30-40 mm.
  • for floors up to 250 mm thick, the concrete layer must be at least 12 mm. This value varies depending on the diameter of the valve. For overlaps of greater thickness, the thickness of the formation increases by 5 mm;
  • the part of the structure placed in the ground without additional protection should be covered with a layer of concrete from 40 to 76 mm.
  • for foundations, a layer thickness of at least 40 mm is provided.

The parameters of the protective layer are clearly regulated by the norms:

Related materials